We use cookies to improve your experience and save your reports. Privacy Policy

Every industrial symbiosis proposal dies in validation.This is the validation.

The question is never whether the stream has value. It is whether the numbers survive a technical review — and answering that has meant a feasibility study measured in months. Below is what replaces it: a route dossier computed from a real stream, where every reported figure is either derived from a balance that closed or is a declared input carrying its source.

How the engine gets these numbers →

A worked dossier, as the engine emits it

SP-7 M5 demo
============

Physical
--------
  COMPUTED  Combustion LHV (Hess's law)                                                        32619.10 MJ  [SOURCED]
      combustion LHV by Hess's law, H2O(g) reference state (D-A/D-B)
  COMPUTED  Free-moisture penalty (charged against LHV)                                        -128.50 MJ  [SOURCED]
      the stream's own free water, driven off before any of the fuel value can be used (D-C) -
      distinct from the combustion hydrogen's H2O(g) product, already inside the LHV total above
  COMPUTED  Flue-gas sensible heat loss (charged against LHV)                                  -1786.97 MJ  [SOURCED]
      sigma=1.302e+06
      the combustion products' own sensible heat, carried away cooling from 298.15 K to 423.15 K
      (D-F) - distinct from the free-moisture penalty above and from the H2O(g) product term
      already inside the LHV total
  COMPUTED  Net usable energy (LHV less moisture penalty less flue-gas sensible heat) - TOTAL  30703.63 MJ (sigma: n/a - see note)  [SOURCED]
      the sum of the 3 lines above, 298.15 -> 423.15 K

Economics
---------
  COMPUTED  Net Usable Energy (priced)                                                         $363.77  [CLIENT]
      the Physical section's total, priced against the client gas basis
  COMPUTED  Landfill/Tipping Fees Avoided                                                      $0.00  [CLIENT]
      priced against the client landfill/tipping-fee basis
  COMPUTED  Processing/Transport Deductions                                                    $0.00  [CLIENT]
      priced against the client transport/processing basis (a magnitude - net_financial_impact()
      negates it before summing)
  COMPUTED  Net Financial Impact                                                               $363.77  [CLIENT]
      the sum of the three priced terms above
  COMPUTED  Net Annual Benefit                                                                 $1,818,839.22  [CLIENT]
      Net Financial Impact multiplied by the client's declared annual throughput

Where sigma collapsed, and what collapsed it:
  Net usable energy (LHV less moisture penalty less flue-gas sensible heat) - TOTAL: combustion_lhv()'s product-moles terms are built by hand-multiplying product_moles (an uncited operand) against a cited formation enthalpy, so they carry no sigma of their own (R36) - Rule 4 (D-E) collapses this composed total to sigma=None even though flue_gas_sensible_heat()'s own sub-balance total carries a real, positive sigma

Why this survives review

Lookup tables answer questions. This closes them. Mass closes, energy closes, charge closes, elements close — and where a balance could not close, the dossier says so on the line rather than filling the gap with a plausible number. That is the whole property being offered: nothing in the output is asserted without either a closure behind it or a declared origin in front of it.

Run this on your stream

The dossier above was computed from a published stream analysis. Send the analysis for yours and an engineer will walk through the result with your technical team.

This is the input the dossier is computed from. Without it there is nothing to close a balance on.

Optional. If you have a lab report, you can upload it instead of pasting.