Every industrial symbiosis proposal dies in validation.This is the validation.

The question is never whether the stream has value. It is whether the numbers survive a technical review — and answering that has meant a feasibility study measured in months. Below is what replaces it: a route dossier computed from a real stream, where every reported figure is either derived from a balance that closed or is a declared input carrying its source.

How the engine gets these numbers →

Request a qualificationAbout the simulation engine

A worked dossier, as the engine emits it

Validation dossier · published stream

Spent Toluene/Methanol Solvent Blend - Published Validation Dossier

Physical

  1. Combustion LHV (Hess's law)32619.10 MJ

    combustion LHV by Hess's law, H2O(g) reference state

    SOURCED
  2. Free-moisture penalty (charged against LHV)-128.50 MJ

    the stream's own free water, driven off before any of the fuel value can be used - distinct from the combustion hydrogen's H2O(g) product, already inside the LHV total above

    SOURCED
  3. Flue-gas sensible heat loss (charged against LHV)-1786.97 MJ

    the combustion products' own sensible heat, carried away cooling from 298.15 K to 423.15 K - distinct from the free-moisture penalty above and from the H2O(g) product term already inside the LHV total

    uncertainty ± 1.30 MJSOURCED
  4. Net usable energy (LHV less moisture penalty less flue-gas sensible heat) - TOTAL30703.63 MJ

    the sum of the 3 lines above, 298.15 -> 423.15 K

Economics

  1. Net Usable Energy (priced)$363.77

    the Physical section's total, priced against the client gas basis

    CLIENT
  2. Landfill/Tipping Fees Avoided$0.00

    priced against the client landfill/tipping-fee basis

    CLIENT
  3. Processing/Transport Deductions$0.00

    priced against the client transport/processing basis (a magnitude - it is subtracted when the terms are summed)

    CLIENT
  4. Net Financial Impact$363.77

    the sum of the three priced terms above

    CLIENT
  5. Net Annual Benefit$1,818,839.22

    Net Financial Impact multiplied by the client's declared annual throughput

    CLIENT

† Where the uncertainty could not be stated, and why:

Net usable energy (LHV less moisture penalty less flue-gas sensible heat) - TOTAL: the heat released by burning the stream is built from an amount of combustion product that is not itself cited to a source, so that term carries no stated uncertainty of its own - and a total cannot be more certain than its parts, so this total states none, even though the flue-gas heat loss on its own does carry one

Why this survives review

A figure on its own answers a question. A closed balance settles it. Mass closes, energy closes, charge closes, elements close — and where a balance could not close, the dossier says so on the line rather than filling the gap with a plausible number. That is the whole property being offered: nothing in the output is asserted without either a closure behind it or a declared origin in front of it.

Run this on your stream

The dossier above was computed from a published stream analysis. Tell us the stream and we reply with the routes the engine can evaluate for it — or choose “Request a qualification” and send the analysis for the full dossier.

What do you need?

An engineer replies within 1 business day. That reply confirms what is needed to run the dossier and when it can follow. A route the engine does not cover yet is reported as not yet evaluable, with the evidence that would change that.