We use cookies to improve your experience and understand how the site is used. Privacy Policy

Hazard Class 3Packing Group I

UN Number

UN3165

Aircraft hydraulic power unit fuel tank (containing a mixture of anhydrous hydrazine and monomethyl hydrazine) (M86 fuel)

UN3165 is the identification number that the 49 CFR 172.101 Hazardous Materials Table assigns to "Aircraft hydraulic power unit fuel tank (containing a mixture of anhydrous hydrazine and monomethyl hydrazine) (M86 fuel)". It is listed under Class 3 — Flammable Liquid. The Table gives it packing group I and label codes 3, 6.1, 8. Per-package limits: passenger aircraft or rail Forbidden, cargo aircraft only 42 L.

Official source: 49 CFR 172.101 (eCFR)

Hazardous Materials Table entry

One row in 49 CFR 172.101 for UN3165.

Sym.DescriptionClassPGLabelsSpecial provisions8A8B8C9A9B10A10B
—Aircraft hydraulic power unit fuel tank (containing a mixture of anhydrous hydrazine and monomethyl hydrazine) (M86 fuel)3I3, 6.1, 8—None172NoneForbidden42 LE21, 40, 49, 100
  • Sym.: Column 1 symbols, 49 CFR 172.101(b).
  • Description: Column 2, the proper shipping name, 172.101(c).
  • Class: Column 3, hazard class or division, 172.101(d).
  • PG: Column 5, packing group, 172.101(f).
  • Labels: Column 6, label codes, 172.101(g).
  • Special provisions: Column 7, codes explained in 49 CFR 172.102, 172.101(h).
  • 8A / 8B / 8C: Packaging exceptions, non-bulk and bulk sections of 49 CFR part 173 (an entry of 202 means 173.202), 172.101(i).
  • 9A / 9B: Maximum quantity per package on passenger aircraft or rail, and on cargo aircraft only, 172.101(j).
  • 10A / 10B: Vessel stowage location and other stowage and handling codes, 172.101(k).

Class 3 — Flammable Liquid

See the full class list

A flammable liquid (Class 3) is a liquid having a flash point of not more than 60°C (140°F), or any material in a liquid phase with a flash point at or above 37.8°C (100°F) that is intentionally heated and offered for transportation at or above its flash point in a bulk packaging.

Source: 49 CFR 173.120 (eCFR).